- Determination of Vibration Speed and Noise Level at Deep Well Pumping Plants
Determination of Vibration Speed and Noise Level at Deep Well Pumping Plants
Authors : Sedat Çalişir, Cevat Aydin, Hakan O Mengeş
Pages : 49-54
View : 10 | Download : 15
Publication Date : 2006-04-25
Article Type : Research Article
Abstract :In this study, vibration speed and noise level were investigated at deep well (vertical line shaft) irrigation pumping plants. The vibration speeds of electric motor, coupling and pump discharge head values of investigated plants were found 11.23 ± 1.37, 7.32 ± 1.67 and 5.38 ± 0.93 mm/s respectively. According to the ISO 2372, it was determined that 34.6% of pumping plants were operated in unacceptable conditions, in terms of vibration speed of coupling. Generally, the noise levels of pumping plants were measured as 85.8 ± 5.5 dB(A).Keywords : Sulama pompaj tesisi, derin kuyu pompası, titreşim hızı, gürültü düzeyi.