- Atatürk Üniversitesi Diş Hekimliği Fakültesi Dergisi
- Vol: 29 Issue: 1
- KONİK IŞINLI BİLGİSAYARLI TOMOGRAFİ KULLANILARAK İNFRAORBİTAL KANAL VE SULKUSUN RETROSPEKTİF OLARAK ...
KONİK IŞINLI BİLGİSAYARLI TOMOGRAFİ KULLANILARAK İNFRAORBİTAL KANAL VE SULKUSUN RETROSPEKTİF OLARAK İNCELENMESİ
Authors : Saadettin Dağistan, Özkan Miloğlu, Oğuzhan Altun, Esra Karapinar Umar, Talat - Ezmeci
Pages : 1-6
Doi:10.17567/ataunidfd.522559
View : 21 | Download : 12
Publication Date : 2019-01-15
Article Type : Research
Abstract :Amaç: Bu çalışmanın amacı infraorbital kanal (İOK) ve infraorbital sulkusun (İOS) anatomik lokalizasyonunun konik ışınlı bilgisayarlı tomografi (KIBT) kullanılarak incelenmesidir. Materyal ve Metot: Çalışmamızda 125 hastanın KIBT görüntüleri retrospektif olarak incelenerek İOK ve İOS’nin anatomik özellikleri belirlendi. Bulgular: İOK uzunluğu 11.73 ± 1.90 mm, İOS uzunluğu 16.15 ± 2.90 mm, ikisi arasındaki açı 154.3 ± 8.57° ve kanalın doğrultusunun horizontal düzlem ile yaptığı açı 41.02 ± 7.60° ölçüldü. Sonuç: Bu çalışma KIBT’nin cerrahi olarak önem taşıyan anatomik noktaların mesafelerini belirleyerek maksillofasiyal cerrahi sırasında nörovasküler yapıların hasar görmesinin önlenmesi, lokal anestezi uygulamaları ve diğer invaziv işlemler için yol gösterici olabileceğini ortaya koyuyor. Anahtar Kelimeler: Konik ışınlı bilgisayarlı tomografi, infraorbital kanal, infraorbital sulkus RETROSPECTIVE MORPHOMETRIC ANALYSIS OF THE INFRAORBITAL CANAL AND INFRAORBITAL SULCUS WITH CONE BEAM COMPUTED TOMOGRAPHY ABSTRACT Aim: The aim of our study is to evaluate of anatomical localization of infraorbital foramen, canal and sulcus by using cone beam computed tomography. Material and Method: In this descriptive study, cone beam computed tomography images of 125 patients were retrospectively analyzed. Infraorbital canal and sulcus’s anatomic variation are determined. Results: The average length of infraorbital canal was 11.73 ± 1.90 mm, infraorbital sulcus was 16.15±2.90 mm, the angle between two of them was 154.3 ± 8.57° and the angle between the horizontal plane and the direction of the channel was 41.02 ± 7.60°. Conclusion: This study suggests that cone beam computed tomography may lead the way for prevention of damage to neurovascular structures during maxillofacial surgery by determining the distance of surgically important anatomical landmarks, local anesthesia practices and other invasive procedures. Key Words: Cone beam computed tomography, infraorbital canal, infraorbital sulcusKeywords : Konik ışınlı bilgisayarlı tomografi, infraorbital kanal